进入练习 / 模拟考试 »1.Each of the ______________________ systems has a fire shutoff valve in its line upstream of its engine- driven pump.
- The blue and yellow
- The green and yellow ✓
- The green and blue
正确答案:The green and yellow · A320 · 来源 Chair Flight A320 Question Bank
2.The fire shut off valve closes when:
- The master switch is set to off.
- The fire PB is released out. ✓
- Automatically if a fire is detected.
正确答案:The fire PB is released out. · A320 · 来源 Chair Flight A320 Question Bank
3.The engine 2 fire valve is between the yellow reservoir and:
- The engine 2 hydraulic pump. ✓
- The yellow electric pump.
- The yellow hand pump.
正确答案:The engine 2 hydraulic pump. · A320 · 来源 Chair Flight A320 Question Bank
4.When the smoke detector in the air extraction duct of the avionics ventilation system detects smoke for more than 5 seconds: -A single chime sounds. -The MASTER CAUTION lights, on the glareshield, light up. -The ECAM displays a caution on the E/WD. -The SMOKE light, on the EMER ELEC PWR panel, lights up. -The BLOWER and EXTRACT FAULT, on the VENTILATION panel, light up
- True ✓
- False
正确答案:True · A320 · 来源 Chair Flight A320 Question Bank
5.Where are the engine fire detectors located?
- In the fan and the turbine.
- In the pylon, the fan and the core. ✓
- In the core and the gearbox.
正确答案:In the pylon, the fan and the core. · A320 · 来源 Chair Flight A320 Question Bank
6.When engine FIRE pushbutton is released out, which corresponding valves are closed?
- The low-pressure and the high pressure fuel valve
- The low-pressure fuel valve, the hydraulic fire shut off valve, the engine bleed valve and the pack flow valve ✓
- The crossfeed fuel valve, the hydraulic fire shut off valve, the pack flow valve and the engine bleed valve
- The high-pressure fuel valve, the hydraulic fire shut off valve, the engine bleed valve and the outflow valve
正确答案:The low-pressure fuel valve, the hydraulic fire shut off valve, the engine bleed valve and the pack flow valve · A320 · 来源 Chair Flight A320 Question Bank
7.The FIRE light identifies the engine to be shutdown because of fire. The light flashes for five seconds then comes on red when an engine fire warning is triggered.
- True.
- False ✓
正确答案:False · A320 · 来源 Chair Flight A320 Question Bank
8.Each lavatory wastebin has ____________ fire extinguishing system.
- an automatic ✓
- a manual
- a semi-automatic
正确答案:an automatic · A320 · 来源 Chair Flight A320 Question Bank
9.The FIRE TEST PB on the ENG FIRE panel permits the flight crew to test the operation of the fire detection and extinguishing system: A continuous repetitive chime sounds, the MASTER WARN lights flash, ENG FIRE warning appears on ECAM. On the FIRE panel: The ENG FIRE P/B lights up red, the SQUIB lights come on white if discharge supplies are available, the DISCH lights come on amber. On the ENG panel (pedestal): The FIRE lights come on red.
- True ✓
- False
正确答案:True · A320 · 来源 Chair Flight A320 Question Bank
10.The lavatory smoke detection system consists of:
- Two smoke detectors in each lavatory
- One smoke detector in each lavatory ✓
- Three smoke detectors in each lavatory
正确答案:One smoke detector in each lavatory · A320 · 来源 Chair Flight A320 Question Bank
11.When the engine fire push button is released out, which aircraft systems are isolated?
- Fuel, Electricity and Air Systems
- Fuel, Hydraulic and Air Systems
- Fuel, Air, Electricity and Hydraulic Systems ✓
- Fuel system only
正确答案:Fuel, Air, Electricity and Hydraulic Systems · A320 · 来源 Chair Flight A320 Question Bank
12.The FIRE TEST PB on the ENG FIRE panel is pushed to test the operation of the fire detection and extinguishing system. One of the white SQUIB lights will not illuminate. What does that mean?
- one loop is faulty
- both loops are faulty
- the fire detection unit fails
- the discharge supplies are not available ✓
正确答案:the discharge supplies are not available · A320 · 来源 Chair Flight A320 Question Bank
13.Which statement is NOT true? The fire warning ( ENG ) appears in case of:
- a fire signal from both loop A and B
- a fire signal from one loop when the other is faulty
- breaks in both loops occurring within 20 seconds of each other (flame effect) ✓
- a test performed on the control panel
正确答案:breaks in both loops occurring within 20 seconds of each other (flame effect) · A320 · 来源 Chair Flight A320 Question Bank
14.A fire warning (ENG) appears in case: (more than one answer may be correct)
- of a fire signal from both loops A and B
- of breaks in both loops occuring within 5 seconds of each other (flame effect)
- a break in loop A occurs
- 1,2 ✓
正确答案:1,2 · A320 · 来源 Chair Flight A320 Question Bank
15.A fire extinguishing system protects the FWD and AFT cargo compartments. One fire bottle supplies ___ nozzles ( ___ in FWD and ___ in AFT compartment ):
- 4nozzles(2FWD/2AFT)
- 2nozzles(1FWD/1AFT)
- 3nozzles(1FWD/2AFT) ✓
- 3nozzles(2FWD/1AFT)
正确答案:3nozzles(1FWD/2AFT) · A320 · 来源 Chair Flight A320 Question Bank
16.The lavatory has __ smoke detector(s) and __ automatic fire extinguishing system(s) for the wastebin:
- 1 smoke detector and 2 extinguishing systems
- 2 smoke detectors and 1 extinguishing system
- 1 smoke detector and 1 extinguishing system ✓
- 2 smoke detectors and 2 extinguishing systems
正确答案:1 smoke detector and 1 extinguishing system · A320 · 来源 Chair Flight A320 Question Bank
17.The engine 1(2) fire is triggered when:
- all three loops detect a fire (fan, pylon and hot section area)
- a temperature of more than 725 degrees C is detected in the turbine hot section
- a fire is detected by both loops or by one loop, the other one being faulty, or when there is a break in both loops within 5 seconds ✓
- a fire is detected by on loop, followed by the second loop within maximum 10 seconds
正确答案:a fire is detected by both loops or by one loop, the other one being faulty, or when there is a break in both loops within 5 seconds · A320 · 来源 Chair Flight A320 Question Bank
18.Aircraft Fire Protection Systems are comprised of:
- Fire and overheat protection for engines, fire and smoke detection for APU, smoke detection for cargo compartments, avionic bay and lavatories
- Fire and overheat protection for engines and APU, overheat protection for avionic bay, smoke detection for cargo compartments and lavatories
- Fire and overheat protection for engines and APU, fire detection for wheels, smoke detection for cargo compartments, avionic bay and lavatories
- Fire and overheat protection for engines and APU, smoke detection for cargo compartments, avionic bay and lavatories ✓
正确答案:Fire and overheat protection for engines and APU, smoke detection for cargo compartments, avionic bay and lavatories · A320 · 来源 Chair Flight A320 Question Bank
19.Which situation does not cause a fire warning?
- A fire signal from both loop A and B
- A fire signal from loop A and a faulty loop B
- Failure of loop B after a dispatch with a faulty loop A ✓
- Breaks in both loops occurring within 5s of each other
正确答案:Failure of loop B after a dispatch with a faulty loop A · A320 · 来源 Chair Flight A320 Question Bank
20.How many fire extinguishers are provided for each engine?
- 1
- 2 ✓
- 3
- 4
正确答案:2 · A320 · 来源 Chair Flight A320 Question Bank
21.Smoke detection systems are installed in:
- Avionics bay and cargo compartments only
- Avionics bay, cargo compartments and lavatories only ✓
- Avionics bay, cargo compartments, lavatories and engine nacelles
- Avionics bay, cargo compartments, lavatories and galleys
正确答案:Avionics bay, cargo compartments and lavatories only · A320 · 来源 Chair Flight A320 Question Bank
22.Which answer about the fire detection system is correct:
- A fault in one loop does not affect the warning system ✓
- If the system detects an APU fire while the aircraft is on ground, it shuts down the APU automatically but the extinguisher must be discharged manually
- The engine fire detection system consists of 4 sensing elements: pylon nacelle, engine core, turbine section and gear box section
- The fire warning will be triggered in case of one of two operative loops has detected a fire / presence of heat
正确答案:A fault in one loop does not affect the warning system · A320 · 来源 Chair Flight A320 Question Bank
23.The Fire warning appears in case of:
- A fire signal from loop A and B
- Breaks in both loops occuring within 5s of each other
- A fire signal from one loop when the other is faulty
- All answers are correct ✓
正确答案:All answers are correct · A320 · 来源 Chair Flight A320 Question Bank
24.Which statement about the cargo smoke detection and cargo fire extinguishing system is correct:
- The cargo smoke detection consists of 6 smoke detectors (3 Cavities - 1 fwd & 2 aft). The extinguishing system of one extinguishing bottle is connected to 1 nozzle in fwd and two nozzles in aft cargo compartment ✓
- The fire extinguishing bottle must only be used in case of confirmed cargo fire (ECAM warning: FIRE FWD (AFT) CARGO FIRE)
- The cargo smoke/fire detection system senses smoke via the smoke detectors located in the ventilation system outlet and heat sensing elements installed in the roof of each cargo compartment
- The fire extinguishing bottle can be discharged in both cargo compartments simultaneously if needed. But only if both DISCH pb are pushed within 3 seconds
正确答案:The cargo smoke detection consists of 6 smoke detectors (3 Cavities - 1 fwd & 2 aft). The extinguishing system of one extinguishing bottle is connected to 1 nozzle in fwd and two nozzles in aft cargo compartment · A320 · 来源 Chair Flight A320 Question Bank
25.Where is NO fire extinguishing system installed ?
- n the Cargo compartments
- In the Engine No. 1 Cowling
- In the APU compartment
- In the Avionics compartment ✓
正确答案:In the Avionics compartment · A320 · 来源 Chair Flight A320 Question Bank
26.With reference to cargo compartment fire extinguishing, which statement is true?
- There are two fire bottles, one for the FWD compartment and one for the AFT.
- There is only one fire bottle; pressing either DISCH pb discharges it into both compartments.
- There is only one fire bottle, when it is discharged both amber DISCH lights come on. ✓
- There are two fire bottles, when the DISCH pb is pressed they are both discharged into the appropriate compartment.
正确答案:There is only one fire bottle, when it is discharged both amber DISCH lights come on. · A320 · 来源 Chair Flight A320 Question Bank
27.One smoke detector in the air extraction duct of the avionics ventilation system detects smoke in the avionics compartment. When it detects smoke for more than 5 s:
- The ECAM displays a warning on the E/WD
- The ECAM displays a caution on the E/WD ✓
- The ECAM displays an advisory on the E/WD
- There is no warning on the E/WD
正确答案:The ECAM displays a caution on the E/WD · A320 · 来源 Chair Flight A320 Question Bank
28.The cargo compartments have a smoke detection system. Cavities in the cargo compartment ceiling panels each hold two smoke detectors. Each detector is linked to one of the two detection loops (dual loop principle).
- The aft cargo compartment has one cavity, the forward has two cavities.
- The forward compartment has one cavity, the aft has two cavities. ✓
- Both forward & aft compartments have two cavities.
- Both forward & aft compartments have one cavity.
正确答案:The forward compartment has one cavity, the aft has two cavities. · A320 · 来源 Chair Flight A320 Question Bank
29.When is the engine fire shut-off valve closed?
- Automatically every time the engine is stopped
- When the corresponding ENG FIRE pushbutton is released (out) ✓
- Only if a leak is detected in the pylon
- When the hydraulic reservoir reaches low level
正确答案:When the corresponding ENG FIRE pushbutton is released (out) · A320 · 来源 Em42 A320 FAM ATA 30,35,29
30.The HALON fire extinguisher should be used on what type fires?
- Electrical fires only
- Electrical and burning metals
- Electrical and flammable liquid fires ✓
- Electrical and ordinary combustibles
正确答案:Electrical and flammable liquid fires · A320 · 来源 A320 HANDBOOK (general ATA)
31.The avionics compartment is the only area where there is no fire extinguishing system installed
- true ✓
- false
正确答案:true · A320 · 来源 A320 HANDBOOK (general ATA)
32.The aircraft has dual fire detector loops to ensure that a fault in one fire loop will not affect fire detection capabilities
- true ✓
- false
正确答案:true · A320 · 来源 A320 HANDBOOK (general ATA)
33.Which of the following have automatic fire extinguishing systems?
- APU, and lavatory waste bins ✓
- APU, lavatory waste bins and avionics bay
- APU, aft cargo, forward cargo, lavatory waste bins and avionics bay
- APU, forward and aft cargo, lavatory and waste bins
正确答案:APU, and lavatory waste bins · A320 · 来源 A320 HANDBOOK (general ATA)
34.If an engine fire is detected, when will the pedestal mounted red FIRE annunciator light extinguish?
- When the crew pushes the red MASTER WARN push button
- Only after the fire warning no longer exists ✓
- Only after the crew selects the adjacent ENG MASTER switch to off
正确答案:Only after the fire warning no longer exists · A320 · 来源 A320 HANDBOOK (general ATA)
35.What systems are affected when the guarded red ENGINE FIRE push button is pushed and released?
- The Master Warning and the chime will be canceled and the AGENT pb's will be armed
- All fluids, pneumatics and electrics relating to that engine are shut off
- Both are correct ✓
正确答案:Both are correct · A320 · 来源 A320 HANDBOOK (general ATA)